Coaxial surge protector low frequency
CXP09-N/FF
Part Number 631655
- Coaxial surge protector low frequency
- Imax : 20 kA
- Up to 1 GHz
- Connector N
CXP protectors are based on GDT to provide high discharge current capability without destruction. Its particular mounting allows good adaptation to radio and TV system. Typical applications include radio terminals and TV sets (antenna, cable or satellite).
Select another reference:
Network
|
Coaxial DC-1000 MHz | |
Nominal line voltage
|
Un | < 50 V |
Max. DC operating voltage
|
Uc | < 60 Vdc |
Max. frequency
|
f max. | DC-1 GHz |
Insertion loss
|
< 0,2 dB | |
Return loss
|
> 20 dB | |
Impedance
|
50 ohms | |
VSWR
|
<1.2:1 | |
Max. load current @25°C
|
IL | 0.5 A |
Operating current
Continious current at Uc
|
Ic | None |
Max. discharge current
max. withstand @ 8/20 µs by pole
|
Imax | 20 kA |
Protection mode(s)
|
Common mode | |
Protection level
@ In (8/20µs)
|
Up | < 600 V |
Impulse current
2 x 10/350µs Test - D1 Category
|
Iimp | 2.5 kA |
Nominal discharge current
C2 Category
|
In | 5 kA |
Max Power
|
25 W | |
DC Pass
|
Yes | |
Insulation resistance
|
IR | ≥10 GOhms |
Technology
|
Gas discharge tube | |
Connection to Network
|
Connector N Female/Female | |
Format
|
Metallic box | |
Mounting
|
On plate | |
Housing material
|
Brass | |
Operating temperature
|
Tu | -40/+85°C |
Protection rating
|
IP20 | |
Outdoor application
|
No | |
Failsafe mode
|
Short-circuit | |
Disconnection indicator
|
Transmission interrupt - default mode 2 | |
Dimensions
|
See diagram |
Standards compliance
|
IEC 61643-21 / EN 61643-21 / UL497E |