Coaxial surge protector DC-3.5 GHz
P8AX09-N/FF/HE
Part Number 600114
- RF coaxial surge protector
- Harsh environment (HE)
- 3.5 GHz
- Connectors : N
- Low insertion loss
- Removale GDT
- DC-pass
- Bi-directional protection
The P8AX series is based on gas discharge tube (GDT) and designed for RF line surge protection.
Available for different power and with coaxial connectors, P8AX units could be provide in feedthrough mounting version and with various impedance.
Select another reference:
Max. DC operating voltage
|
Uc | 72 Vdc |
Frequency range
|
f | DC-3.5 GHz |
Insertion loss
|
< 0.2 dB | |
Return loss
|
> 20 dB | |
Impedance
|
50 ohms | |
VSWR
|
<1.2:1 | |
Max. load current @25°C
|
IL | 10 A |
Residual Current
Leakage current to Ground
|
Ipe | None |
Operating current
Continious current at Uc
|
Ic | None |
Max. discharge current
max. withstand @ 8/20 µs by pole
|
Imax | 20 kA |
Protection mode(s)
|
Common mode | |
Protection level
@1kV/µs (C3)
|
Up | < 650 V |
Impulse current
2 x 10/350µs Test - D1 Category
|
Iimp | 1 kA |
Nominal discharge current
C2 Category
|
In | 5 kA |
Max Power
|
25 W | |
Typical let through energy
(50 ohms) input 4kV 1.2/50μs - 2kA 8/20μs
|
300 µJ | |
DC Pass
|
Yes | |
Insulation resistance
|
IR | ≥10 GOhms |
Technology
|
Gas discharge tube | |
Connection to Network
|
Connector N Female/Female | |
Mounting
|
Feedthrough | |
Housing material
|
Brass/Surface plating: Sn Ni | |
Operating temperature
|
Tu | -40/+85°C |
Protection rating
|
IP66 | |
Outdoor application
|
Yes | |
Failsafe mode
|
Short-circuit | |
Disconnection indicator
|
Transmission interrupt | |
Spare module(s)
|
BBHF-90V | |
Dimensions
|
See diagram | |
Contacts
|
Bronze/Surface Gold or Silver | |
Weight
|
0.135 kg |
Standards compliance
|
IEC 61643-21 / EN 61643-21 / UL497E | |
RohS compliance
|
Yes |